1

VCT

60227 IEC 52 VCT

300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

Round type for mobile-electrical equipment used in mines, factories, farm or household appliances.

VAF-G

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED WITH GROUND, FLAT TYPE

Conductor Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Ground wire Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Insulation Polyvinyl chloride (PVC/C)
2 Core : Blue and Brown
Ground-Cores : Green/Yellow
Core identification White polyvinyl chloride (PVC/ST4)
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 300/500 Volts
300 Volts between Line-to-Earth
500 Volts between Line-to-Line
Testing voltage 2,000 Volts
Reference standard TIS 11 Part 101-2553, Table 1

VAF-G SPEC

VAF

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

Conductor Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Insulation Polyvinyl chloride (PVC/C)
2 Core : Blue and Brown
Core identification White polyvinyl chloride (PVC/ST4)
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 300/500 Volts
300 Volts between Line-to-Earth
500 Volts between Line-to-Line
Testing voltage 2,000 Volts
Reference standard TIS 11 Part 101-2553, Table 1

VAF SPEC

THW (f)

60227 IEC 02 THW (f)

450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED , SINGLE CORE

Indoor fixed installation in dry location, for electrical panels connection or for electrical apparatus.

Conductor Flexible annealed copper wire Size 1.5 mm² up to 240 mm²
Insulation Polyvinyl chloride (PVC/C)
Core identification Single – core : Any color
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 450/750 Volts
450 Volts between Line-to-Earth
750 Volts between Line-to-Line

Testing voltage 2,500 Volts
Reference standard TIS 11 Part 3-2553, Table 3

VAFf SPEC

THW

60227 IEC 01 THW

450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED, SINGLE CORE

Building wiring for installation on insulator or in race way, dry location.

Conductor Solid and stranded annealed copper Size 1.5mm² up to 400 mm²
Insulation Polyvinyl chloride (PVC/C)
Core identification Single – core : Any color
Classification Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 450/750 Volts
450 Volts between Line-to-Earth
750 Volts between Line-to-Line
Testing voltage 2,500 Volts
Reference standard TIS 11 Part 3-2553, Table 1

TWH SPEC