60227 IEC 52 VCT
300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE
Round type for mobile-electrical equipment used in mines, factories, farm or household appliances.
60227 IEC 52 VCT
300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE
Round type for mobile-electrical equipment used in mines, factories, farm or household appliances.
300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED WITH GROUND, FLAT TYPE
Conductor |
Solid and stranded annealed copper, Size 1 mm² up to 16 mm² |
---|---|
Ground wire |
Solid and stranded annealed copper, Size 1 mm² up to 16 mm² |
Insulation |
Polyvinyl chloride (PVC/C) 2 Core : Blue and Brown Ground-Cores : Green/Yellow |
Core identification | White polyvinyl chloride (PVC/ST4) |
Outer sheath | Maximum conductor temperature 70°C |
Classification |
Circuit voltage not exceeding 300/500 Volts 300 Volts between Line-to-Earth 500 Volts between Line-to-Line |
Testing voltage | 2,000 Volts |
Reference standard | TIS 11 Part 101-2553, Table 1 |
300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE
Conductor |
Solid and stranded annealed copper, Size 1 mm² up to 16 mm² |
---|---|
Insulation |
Polyvinyl chloride (PVC/C) 2 Core : Blue and Brown |
Core identification | White polyvinyl chloride (PVC/ST4) |
Outer sheath | Maximum conductor temperature 70°C |
Classification |
Circuit voltage not exceeding 300/500 Volts 300 Volts between Line-to-Earth 500 Volts between Line-to-Line |
Testing voltage | 2,000 Volts |
Reference standard | TIS 11 Part 101-2553, Table 1 |
60227 IEC 02 THW (f)
450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED , SINGLE CORE
Indoor fixed installation in dry location, for electrical panels connection or for electrical apparatus.
Conductor | Flexible annealed copper wire Size 1.5 mm² up to 240 mm² |
---|---|
Insulation | Polyvinyl chloride (PVC/C) |
Core identification | Single – core : Any color |
Outer sheath | Maximum conductor temperature 70°C |
Classification |
Circuit voltage not exceeding 450/750 Volts 450 Volts between Line-to-Earth 750 Volts between Line-to-Line |
Testing voltage | 2,500 Volts |
Reference standard | TIS 11 Part 3-2553, Table 3 |
60227 IEC 01 THW
450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED, SINGLE CORE
Building wiring for installation on insulator or in race way, dry location.
Conductor | Solid and stranded annealed copper Size 1.5mm² up to 400 mm² |
---|---|
Insulation | Polyvinyl chloride (PVC/C) |
Core identification | Single – core : Any color |
Classification | Maximum conductor temperature 70°C |
Classification |
Circuit voltage not exceeding 450/750 Volts 450 Volts between Line-to-Earth 750 Volts between Line-to-Line |
Testing voltage | 2,500 Volts |
Reference standard | TIS 11 Part 3-2553, Table 1 |