1

0.6/1 KV-CV

FD-0.6/1 KV-CV-SWA

0.6/1 KV 90°C CROSS-LINKED POLYETHYLENE INSULATED PVC SHEATHED, WITH GALVANIZED STEEL WIRES ARMORED POWER CABLE

Medium Voltage Power Cables for between Tranformer amd MDB, Cable is easy to bend and easy to work.

NYY

60227 IEC 10 NYY

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED

Exposed installation, or in raceway, wet or dry location or direct burial in ground.

VCT-G

60227 IEC 53 VCT or 60227 IEC 53 VCT-G

300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

Round type with Ground-Wire for mobile-electrical equipment used in mines, factories, farm or household appliances.

VCT

60227 IEC 52 VCT

300/300 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

Round type for mobile-electrical equipment used in mines, factories, farm or household appliances.

VAF-G

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED WITH GROUND, FLAT TYPE

Conductor Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Ground wire Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Insulation Polyvinyl chloride (PVC/C)
2 Core : Blue and Brown
Ground-Cores : Green/Yellow
Core identification White polyvinyl chloride (PVC/ST4)
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 300/500 Volts
300 Volts between Line-to-Earth
500 Volts between Line-to-Line
Testing voltage 2,000 Volts
Reference standard TIS 11 Part 101-2553, Table 1

VAF-G SPEC

VAF

300/500 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED AND SHEATHED, FLAT TYPE

Conductor Solid and stranded annealed copper, Size 1 mm²
up to 16 mm²
Insulation Polyvinyl chloride (PVC/C)
2 Core : Blue and Brown
Core identification White polyvinyl chloride (PVC/ST4)
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 300/500 Volts
300 Volts between Line-to-Earth
500 Volts between Line-to-Line
Testing voltage 2,000 Volts
Reference standard TIS 11 Part 101-2553, Table 1

VAF SPEC

THW (f)

60227 IEC 02 THW (f)

450/750 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED , SINGLE CORE

Indoor fixed installation in dry location, for electrical panels connection or for electrical apparatus.

Conductor Flexible annealed copper wire Size 1.5 mm² up to 240 mm²
Insulation Polyvinyl chloride (PVC/C)
Core identification Single – core : Any color
Outer sheath Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 450/750 Volts
450 Volts between Line-to-Earth
750 Volts between Line-to-Line

Testing voltage 2,500 Volts
Reference standard TIS 11 Part 3-2553, Table 3

VAFf SPEC

THW

60227 IEC 01 THW

450/750 V 70°C SOLID AND STRANDED CONDUCTOR PVC INSULATED, SINGLE CORE

Building wiring for installation on insulator or in race way, dry location.

Conductor Solid and stranded annealed copper Size 1.5mm² up to 400 mm²
Insulation Polyvinyl chloride (PVC/C)
Core identification Single – core : Any color
Classification Maximum conductor temperature 70°C
Classification Circuit voltage not exceeding 450/750 Volts
450 Volts between Line-to-Earth
750 Volts between Line-to-Line
Testing voltage 2,500 Volts
Reference standard TIS 11 Part 3-2553, Table 1

TWH SPEC